Product Details:
Payment & Shipping Terms:
|
Torque: | 1.02~3Nm | Protect Feature: | Waterproof |
---|---|---|---|
Speed(RPM): | 3000rpm | Continuous Current(A): | 10.47~29.16A |
Efficiency: | IE 1 | Length: | 118mm |
Weight: | 2.1kg | Ke (voltage Constant): | 11.4V/krpm |
Rated Peak Current: | 29.16A | Rated Continuous Output Power: | 319W |
High Light: | 12 Slots liquid cooled brushless motor,48V brushless water cooled motor,8 Poles water cooled bldc motor |
12 Slots 8 Poles 3 Phase Water Cooled Brushless DC Motor
Specification | |
Supply voltage (reference) | 48V DC |
Rated continuous torque | 1.02Nm |
Rated speed at cont torque | 3000rpm |
Rated continuous stall current | 10.47A |
Rated continuous output power | 319W |
Rated peak torque | 3Nm |
Rated peak current | 29.16A |
Torque constant | 0.1089Nm/A |
Ke (voltage constant) | 11.4V/krpm |
Terminal resistance | 0.28Ω |
Inductance | 0.8mH |
Insulation class | B |
Rotor inertia | 7.40E-05kg.m² |
Weight | 2.1kg |
Length | 118mm |
1. How could you help me select an appropriate motor solution for my application?
A:The absolute minimum information required to properly select a motor solution is the supply voltage, available continuous and peak current, load torque, speed at load, and desired motor technology (brush or brushless). To be sure, the more application information you can provide, the more accurate and exact motor we can offer or quote to you.
2. How do I calculate the rated speed or the speed at a specific torque for a motor or gearmotor?
A: The output speed for a motor or gearmotor is given by the equation below:
w = [VS - (I x Rmt)] / (KE x N)
Where
w = Speed
VS = Supply Voltage
I = Current (Obtained from previous equation)
Rmt = Motor Terminal Resistance
KE = Back-EMF Constant
N = Gear Ratio (Equals 1 if there is no gearbox)
3. What environmental considerations are there?
A: Typical environmental temps for the motor should be in a low humidity environment with an ambient temperature range of –20 C to +50 C. BLDC motors do have IP ratings associated to them and limited customization can be done to increase the IP rating. If severe conditions require IP ratings of IP54 or higher, a customized motor construction is required to accommodate this need.